The MES20 magnetically-coupled positive displacement pulse output flowmeter, with its nutating disc measurement principle flow chamber, provides a high resolution pulseout, making it suitable for a wide range of precision batching and flowrate monitoring applications, operating over a wide flow range.

The MES20 was introduced in 1995, and is now used throughout the world. It is the primary choice for most construction chemicals suppliers throughtout Australasia for measuring and dispensing liquid admixture chemicals.

The nutating (wobble) disc measurement flow chamber employed in the MES20, makes the meter operate with only minimal headlosses and can pass small impurities without jamming. Measurement with a wide range of varying viscocity and specific gravity liquid water based admixtures is possible with only minimal calibration variations. The optimum operating flow rate is at nominal (Nom) flow, expect at least 10-15 years operating life of the chamber with admixture liquids.

The pulsehead (electronic) is fully self contained unit, which attaches to the main meter body with a bayonet turn and lock fitting mechanism. Although the MES20 was designed primarily for economical measurement of concrete admixtures, it is also used for a wide range of other water based liquid measurement applications.
Features
 
Measures Admixtures (Specific Gravity <= 1.4)

Nutating disc measuring chamber.

Small impurities can pass chamber without jamming.

Low hydraulic thrust minimises wear.

Exclusive 1 millilitre per 1 pulse output.

* 1.5 % accuracy curve.

* 0.2 % repeatability of rate.

Conforms to AS3565-1988, Designed to meet AS3901.
Specification
 
Size:20mm
Pulse output rate:
1/ Transistor: 1 per 1 millilitre(1000/Litre),Transistor output (optional 1 per 10 millilitre (100/Litre)).
2/ Reed switch: 61 per litre, contact closure
Voltage supply: +5 to 25 VDC
Supply current:-
Transistor version : 5mA to 25mA proportional to supply voltage
Reed Switch : switching upto 100mA.
Accuracy (min - max range):+- 1.5 %(repeatability +- 0.2 %)
Start flow @ 5%:0.6 litres per minute
Minimum(Min)flow:1.5 litres per minute
Nominal(Nom)flow:45 litres per minute
Maximum(Max)flow:54 litres per minute(Admix s.g. 1.4)68 litres per minute (Admix s.g. 1.1)75 litres per minute (Water s.g. 1.0)
Maximum working pressure:1160 kPa
Headloss at nominal flow:25 kPa
Maximum fluid temperature:50C
Weight:1.8 kg